33, No. Although there are hybrid Electric Discharge Machining and other advancements are existing in Electric Discharge Machining but Wire electrical discharge machining is widely used for machining the variety of work materials such as alloys and superalloys. For more information view the SAGE Journals Article Sharing page. Brass wire with 0.25mm diameter and Skd 61 alloy steel with 10mm thickness were used as tool and work materials in the experiments. In this paper authors have reviewed the different types of electrical discharge machining, dielectric fluids used in the machining process and effect of peak current, voltage and pulse on time parameters on response parameters like material removal rate and tool wear rate. Besides machining and surface modification of implants, it finds applications in almost all areas of manufacturing industries. It is an electro-thermal machining process where electrical energy is used to generate electrical spark and material removal mainly occurs due to thermal energy of the spark. This research article focuses its attention mainly on surface modification of Ti-based alloys by electric discharge machining process. Sorry, preview is currently unavailable. This article reviews the various research work done on surface modification of Ti alloy by electric discharge machining and attempts to bring out the current scenario … Sharing links are not available for this article. View or download all the content the society has access to. 1346-1353. Jabbaripour, B, Sadeghi, MH, Shabgard, MR. Chattopadhyay, KD, Satsangi, PS, Verma, S. Havlikova, J, Strasky, J, Vandrovcova, M. Wennerberg, A, Zallgren, C, Johansson, C. View or download all content the institution has subscribed to. Publisher of distinguished academic, scientific and professional journals. The International Journal of Advanced Manufacturing Technology, Electric discharge machining – A potential choice for surface modification of metallic implants for orthopedic applications: A review. Electrical discharge machining (EDM) is one of the most extensively used non-conventional material removal processes. investigated in wire electric discharge machining (WEDM) process. Create a link to share a read only version of this article with your colleagues and friends. The area under focus for this research review is orthopedics applications. For this purpose a single and isolated spark is physically and mathematically modelled, and its three phases; viz., Breakdown, Discharge and Erosion are investigated. 1: 1. The main application for EDM is the manufacturing of complex 3D geometries, especially the manufacturing of dies and molds. Electrical discharge machining (EDM) is a non-traditional process based on thermoelectric energy between a work piece and an electrode. (2018). Tribological investigations of wear resistant layers developed through... 3D printed composite materials for craniofacial implants: current conc... A Review on Bio-functionalization of β-Ti Alloys. Experimental research on powder-mixed near-dry electrical discharge surface modification of Ti-... Surfactant and graphite powder–assisted electrical discharge machining of titanium alloy. The feed-forward back-propagation network model was trained to predict the discharge categories of the pulse instances with AE signal inputs which can be used for monitoring the material-removal mechanism in micro-electrical discharge machining operation. In response, the input parameters considered for the experimental work is Pulse on … 3, … The development of the process was the result of seeking a technique to replace the machined electrode used in … A pulse discharge occurs in a small gap between a work piece and an electrode, and removes the unwanted material … [13]. (2017). Powder mixed electric discharge machining (PMEDM) improves the quality of the electric discharge machined surface and reduces the surface defects. Electrical Discharge Machining. Prediction and optimization of process parameters in wire cut electric discharge machining for High-speed steel (HSS) International Journal of Computers and Applications: Vol. This product could help you, Accessing resources off campus can be a challenge. The major challenges faced in EDM are high Tool Wear Rate (TWR), overcut and poor surface quality. Please read and accept the terms and conditions and check the box to generate a sharing link. “Electric discharge machining of Al10%SiC as cast metal matrix composites”, Journal of material processing technology, Vol 155 -156, p.1653-1657. A non-dominated sorting genetic algorithm (NSGA-II) is applied to obtain Pareto optimal solutions in widely used advanced machining processes, i.e., electric discharge machining, electrochemical micromachining, ultrasonic machining, abrasive water jet machining. If you have access to a journal via a society or association membership, please browse to your society journal, select an article to view, and follow the instructions in this box. Electric Discharge Machining (EDM) is one of the most efficiently employed non-traditional machining processes for cutting hard-to-cut materials, to geometrically complex shapes that are difficult to machine by conventional machines. Singh, S.: Optimization of machining characteristics in electric discharge machining of 6061Al/Al 2 O 3 p/20P composites by grey relational analysis. 39, No. Optimum control parameter setting in complex and stochastic type processes is one of the most challenging problems to the process engineers. Electric discharge machining is one of the most popular nonconventional manufacturing methods. … Historical perspective for surface modification of metallic implants by EDM, Summary of current research issues and future directions, An innovative method for surface modification by material migration in EDM, New developments of Ti-based alloys for biomedical applications, Ti based biomaterials, the ultimate choice for orthopaedic implants—a review, Titanium as implant material for osteosynthesis applications, Titanium alloys in total joint replacements—a material science perspective, Biomedical production of implants by additive electro-chemical and physical processes, The effects of combined micron-/submicron-scale surface roughness and nanoscale features on cell proliferation and differentiation, Surface modification of titanium, titanium alloys, and related materials for biomedical applications, Microstructural evolution and strengthening mechanisms in Ti-Nb-Zr-Ta, Ti-Mo-Zr-Fe and Ti-15Mo biocompatible alloys, Microstructural and mechanical characterization of biomedical Ti–Nb–Zr(–Ta) alloys, A new Ti–15Zr–4Nb–4Ta alloy for medical applications, Development of new metallic alloys for biomedical applications, Corrosion resistance, mechanical properties: corrosion fatigue strength and cytocompatibility of new Ti alloys without Al and V, In-body corrosion fatigue failure of a stainless steel orthopaedic implant with a rare collection of different damage mechanisms, Characterization of prematurely failed stainless steel orthopedic implants, Assessment of wrought ASTM F1058 cobalt alloy properties for permanent surgical implants, Biomaterials: past successes and future problems, Investigation of failure mechanism in vitallium 2000 implant, Corrosion fatigue of biomedical metallic alloys: mechanisms and mitigation, Fracture of the cobalt-chromium modular femoral neck component in total hip arthroplasty, Corrosion, fatigue and corrosion fatigue behaviour of metal implant materials, especially titanium alloys, Microstructure and fatigue crack growth mechanisms in high temperature titanium alloys, Mean stress sensitivity in fatigue of α, (α + β) and β titanium alloys, Changes in fatigue life mechanism due to soft grains and hard particles, Fatigue and wear evaluation of Ti–Al–Nb alloys for biomedical applications, Influence of cooling rate on microstructure of Ti–Nb alloy for orthopedic implants, The fatigue crack propagation resistance of Ti–6Al–4V under aqueous saline environments, Corrosion fatigue crack growth in titanium alloys, Effects of various environments on fatigue crack growth in Laser formed and IM Ti–6Al–4V alloys, Long crack growth behavior of implant material Ti–5Al–2.5Fe in air and simulated body environment related to microstructure, Fractography of a neck failure in a double-modular hip implant, Fracture of the modular femoral neck component in total hip arthroplasty, Failure of the modular neck in a total hip arthroplasty, New type of hip arthroplasty failure related to modular femoral components: breakage at the neck-stem junction, Adverse local tissue reaction associated with a modular hip hemiarthroplasty, Total hip arthroplasty modular neck failure, A case of disassociation of a modular femoral neck trunion after total hip arthroplasty, Fracture of a modular femoral neck after total hip arthroplasty: a case report, Early failure of a modular femoral neck total hip arthroplasty component: a case report, Modular femoral neck fracture after primary total hip arthroplasty, Failure analysis of three uncemented titanium alloy modular total hip stems, In vivo severe corrosion and hydrogen embrittlement of retrieved modular body titanium alloy hip implants, Fracture mechanisms of retrieved titanium screw thread in dental implant, Biocompatibility and osteogenesis of refractory metal implants, titanium, hafnium, niobium, tantalum and rhenium, Fatigue performance and cyto-toxicity of low rigidity titanium alloy, Ti–29Nb–13Ta–4.6Zr, Effect of thermomechanical processing on evolution of various phases in Ti–Nb–Zr alloys, Corrosion fatigue behavior of a biocompatible ultrafine-grained niobium alloy in simulated body fluid, Fatigue, fretting fatigue and corrosion characteristics of biocompatible beta type titanium alloy conducted with various thermo-mechanical treatments, Fatigue behavior of arc melted Ti–13Nb–13Zr alloy, Tensile and fatigue evaluation of Ti–15Al–33Nb (At%) and Ti–21Al–29Nb (At%) alloys for biomedical applications, The role of implant surface characteristics in the healing of bone, Underlying mechanisms at the bone-biomaterial interface, Effect of titanium surface-roughness on proliferation, differentiation, and protein-synthesis of human osteoblast-like cells (MG63), Osteoblast-mediated mineral deposition in culture is dependent on surface microtopography, Optimum surface properties of oxidized implants for reinforcement of osseointegration: surface chemistry, oxide thickness, porosity, roughness, and crystal structure, Enhanced bone opposition to a chemically modified SLA titanium surface, Influence of substratum surface chemistry/energy and topography on the human fetal osteoblastic cell line hFOB 1.19: phenotypic and genotypic responses observed in vitro, Enhancing surface free energy and hydrophilicity through chemical modification of microstructured titanium implant surfaces, High surface energy enhances cell response to titanium substrate microstructure, Effect of micrometer-scale roughness of the surface of Ti-6Al-4V pedicle screws in vitro and in vivo, Effect of supramicron roughness characteristics produced by 1-and 2-step acid etching on the osseointegration capability of titanium, Osteogenic cells on bio-inspired materials for bone tissue engineering, Adhesion, growth and differentiation of osteoblasts on surface-modified materials developed for bone implants, Effect of CpTi surface roughness on human bone marrow cell attachment, proliferation, and differentiation, Specific proteins mediate enhanced osteoblast adhesion on nanophase ceramics, Cell adhesion on artificial materials for tissue engineering, Osteoblast-like cells are sensitive to submicron-scale surface structure, The effect of silica nanoparticle modified surfaces on cell morphology, cytoskeletal organization and function, Cells react to nanoscale order and symmetry in their surroundings, Cell behavior of rat calvaria bone cells on surfaces with random nanometric features, Increased functions of osteoblasts on nanophase metals, Microstructure and dry-sliding wear properties of TiC-reinforced composite coating prepared by plasma-transferred arc weld-surfacing process, Sliding wear of titanium nitride thin films deposited on Ti–6Al–4V alloy by PVD and plasma nitriding processes, Characterization and tribological evaluation of MW-PACVD diamond coatings deposited on pure titanium, Fretting wear studies on uncoated, plasma nitrided and laser nitrided biomedical titanium alloys, Plasma nitriding behavior of Ti6Al4V orthopedic alloy, A review of the application of anodization for the fabrication of nanotubes on metal implant surfaces, Development and characterization of laser clad high temperature self-lubricating wear resistant composite coatings on Ti–6Al–4V alloy, Effect of electro-discharging on formation of biocompatible layer on implant surface, The effect of powder suspended dielectrics on the thermal influenced zone by electro discharge machining with small discharge energies, Sliding wear of electrically conductive ZrO, Investigating surface roughness, material removal rate and corrosion resistance in PMEDM of γ-TiAl intermetallic, State of the art electrical discharge machining (EDM), On the effect of electro-discharge machining parameters on the fatigue life of AISI D6 tool steel, Experimental modeling and multiobjective optimization of electrical discharge drilling of aerospace superalloy material, Statistical multi-objective optimization of electrical discharge machining parameters in machining titanium grade 5 alloy using graphite electrode, Influence of dielectric fluids on surface properties of electrical discharge machined titanium alloy, Performance and surface integrity of Ti6Al4V after sinking EDM with special graphite electrodes, The effects of tool materials on machinability, surface topography and corrosion resistance in EDM of γ-TiAl intermetallic, Investigation of machining parameters and surface integrity in wire electric discharge machining of pure titanium, Wire electro-discharge machining of titanium alloy, A mathematical model to predict material removal rate during electric discharge machining of cryogenically treated titanium alloys, Improvement in microhole machining accuracy by polarity changing technique for microelectrode discharge machining on Ti–6Al–4V, Analysis of rotary electrical discharge machining characteristics in reversal magnetic field for copper-en8 steel system, Effect of ultrasonic-assisted EDM on the surface integrity of cemented tungsten carbide (WC-Co), Effect of ultrasonic vibration of tool on electrical discharge machining of cemented tungsten carbide (WC-Co), Parametric optimization of powder mixed electrical discharge machining by response surface methodology, Numerical simulation of powder mixed electric discharge machining (PMEDM) using finite element method, Technology and research developments in powder mixed electric discharge machining (PMEDM), How suspended particles affect surface morphology in powder mixed electrical discharge machining (PMEDM), Study of electrical discharge machining using powder-suspended working media, An experimental investigation on the effect of powder mixed dielectric on machining performance in electric discharge machining, Modelling and experimental investigation on the effect of nanopowder-mixed dielectric in micro-electrodischarge machining of tungsten carbide, Investigation of recast layers generated by a powder-mixed dielectric micro electrical discharge machining process, Improving micro-hardness of stainless steel through powder-mixed electrical discharge machining, Influence of electrical discharge machining process parameters on surface micro-hardness of titanium alloy, Advancing EDM through fundamental insight into the process, The dependence of interspace discharge transitivity upon the gap debris in precision electro-discharge machining, Formation of a crater in the workpiece on an electrical discharge machine, A finite element model of EDM based on the Joule effect, Accretion of titanium carbide by electrical discharge machining with powder suspended in working fluid, After 60 years of EDM, the discharge process remains still disputed, Electrical discharge machining of titanium alloy (Ti–6Al–4V), Effect of electrical-discharging on formation of nanoporous biocompatible layer on titanium, Nanoporous biocompatible layer on Ti–6Al–4V alloys enhanced osteoblast-like cell response, Effect of electrical discharging on formation of nanoporous biocompatible layer on Ti–6Al–4V alloys, Bone regenerative potential of mesenchymal stem cells on a micro-structured titanium processed by W-EDM, Enhanced osteoblast response to electrical discharge machining surface, Surface treatment by electric discharge machining of Ti–6Al–4V alloy for potential application in orthopaedics, Characterization of electric discharge machining, subsequent etching and shot-peening as a surface treatment for orthopedic implants, Innovative surface modification of Ti–6Al–4V alloy with a positive effect on osteoblast proliferation and fatigue performance, Surface characterization and biological evaluation of spark-eroded surfaces, Micro-CT evaluation of in vivo osteogenesis at implants processed by wire-type electric discharge machining, Rapid biocompatible micro device fabrication by micro-EDM, Electro-spark alloying using graphite electrode on titanium alloy surface for biomedical applications, Fatigue endurance of Ti–6Al–4V alloy with electro-eroded surface for improved bone in-growth, The effect of microstructure on fatigue performance of Ti–6Al–4V alloy after EDM surface treatment for application in orthopaedics, Comparison of grinding and wire EDM concerning fatigue strength and surface integrity of machined Ti6Al4V components, Comparative study of mechanical properties using standard and micro-specimens of base materials Inconel 625, Inconel 718 and Ti–6Al–4V, Degradation of titanium 6Al–4V fatigue strength due to electrical discharge machining, Perspectives of the Si3N4-TiN ceramic composite as a biomaterial and manufacturing of complex-shaped implantable devices by electrical discharge machining (EDM), EDM machining capabilities of magnesium (Mg) alloy WE43 for medical applications, Simulation of micro-EDM servomotor for machining micro pits on hip implant, Ultrasonic vibration assisted electro-discharge machining of microholes in Nitinol, Electro discharge machining of nickel–titanium shape memory alloys, Multitechnique characterization of CPTi surfaces after electro discharge machining (EDM), Surface and elemental alterations of dental alloys induced by electro discharge machining (EDM), Development of mirror like surface characteristics using nano powder mixed electric discharge machining (NPMEDM), Role of powder in the machining of Al-10%Sic, Effect of silicon powder mixed EDM on machining rate of AISI D2 die steel, Fabrication of hollow nickel micro-spheres with high degree of hollowness by silicon powder-mixed spark erosion, Surface modification of tungsten carbide by electrical discharge coating (EDC) using a titanium powder suspension, Surface modification process by electrical discharge machining with a Ti powder green compact electrode, The effect in EDM of a dielectric of a urea solution in water on modifying the surface of titanium.